In regulator_list_autoset there is a test for ret being non-zero and
error being zero but it uses the binary '&' instead of the logical '&&'
which could well lead to unexpected results. Correct this to use the
logical '&&' instead.
This issue found by Smatch.
Signed-off-by: Andrew Goodbody <andrew.goodbody@linaro.org>
Reviewed-by: Peng Fan <peng.fan@nxp.com>
Signed-off-by: Peng Fan <peng.fan@nxp.com>
se_desc loop check is wrong, it relies on the desc always has
the expected name to end of the loop. It works because the device tree
has the expected name as of now, but this may not be always true.
Drop se_desc by moving the check into probe and fix the loop check.
Reported-by: Andrew Goodbody <andrew.goodbody@linaro.org>
Cc: Tom Rini <trini@konsulko.com>
Cc: Fabio Estevam <festevam@gmail.com>
Signed-off-by: Peng Fan <peng.fan@nxp.com>
There are two ways to set the output voltage of the LD05
regulator. First by writing to the voltage selection registers
and second by toggling the SD_VSEL signal.
Usually board designers connect SD_VSEL to the VSELECT signal
controlled by the USDHC controller, but in some cases the
signal is hardwired to a fixed low level (therefore selecting
3.3V as initial value for allowing to boot from the SD card).
In these cases, the voltage is only determined by the value
of the LDO5CTRL_L register. Introduce a property
nxp,sd-vsel-fixed-low to let the driver know that SD_VSEL
is low and there is no GPIO to actually get that
information from dynamically.
This is equivalent to the following change in Linux:
c8c1ab2c5cb7 ("regulator: pca9450: Handle hardware with fixed SD_VSEL for LDO5")
Signed-off-by: Frieder Schrempf <frieder.schrempf@kontron.de>
Signed-off-by: Peng Fan <peng.fan@nxp.com>
For LDO5 we need to be able to check the status of the SD_VSEL input in
order to know which control register is used. Read the status of the
SD_VSEL signal via GPIO and use the correct register accordingly.
To use this, the LDO5 node in the devicetree needs the sd-vsel-gpios
property to reference the GPIO that is used to read back the SD_VSEL
status internally. Please note that the SION bit in the IOMUX must be
set if the signal is muxed as VSELECT and controlled by the USDHC
controller.
This is equivalent to the following change in Linux:
3ce6f4f943dd ("regulator: pca9450: Fix control register for LDO5")
Signed-off-by: Frieder Schrempf <frieder.schrempf@kontron.de>
Signed-off-by: Peng Fan <peng.fan@nxp.com>
The LDO5 regulator has two configuration registers, but only
LDO5CTRL_L contains the bits for enabling/disabling the regulator.
This is equivalent to the following change in Linux:
f5aab0438ef1 ("regulator: pca9450: Fix enable register for LDO5")
Fixes: 326337fb00 ("pmic: pca9450: Add regulator driver")
Signed-off-by: Frieder Schrempf <frieder.schrempf@kontron.de>
Signed-off-by: Peng Fan <peng.fan@nxp.com>
In tps65941_buck_val and tps65941_ldo_val hex is an unsigned variable
being assigned the return value from a function that returns int. Change
hex to be an int so that the following test for an error as a negative
value will work as expected.
This issue was found by Smatch.
Signed-off-by: Andrew Goodbody <andrew.goodbody@linaro.org>
Reviewed-by: Frieder Schrempf <frieder.schrempf@kontron.de>
In order to get the expected result from
rzg2l_usbphy_regulator_get_enable the return expression needs
parenthesis so that the binary and is performed before the double
logical not.
This issue was found by Smatch.
Signed-off-by: Andrew Goodbody <andrew.goodbody@linaro.org>
Reviewed-by: Frieder Schrempf <frieder.schrempf@kontron.de>
In palmas_smps_val and palmas_ldo_val hex is an unsigned variable being
assigned the return value from a function that returns int. Change hex
to be an int so that the following test for an error as a negative value
will work as expected.
This issue was found by Smatch.
Signed-off-by: Andrew Goodbody <andrew.goodbody@linaro.org>
Reviewed-by: Frieder Schrempf <frieder.schrempf@kontron.de>
In lp87565_buck_val hex is an unsigned variable being assigned the return
value from a function that returns int. Change hex to be an int so that
the following test for an error as a negative value will work as expected.
This issue was found by Smatch.
Signed-off-by: Andrew Goodbody <andrew.goodbody@linaro.org>
Reviewed-by: Frieder Schrempf <frieder.schrempf@kontron.de>
In lp873x_buck_val and lp873x_ldo_val hex is an unsigned variable being
assigned the return value from a function that returns int. Change hex
to be an int so that the following test for an error as a negative value
will work as expected.
This issue was found by Smatch.
Signed-off-by: Andrew Goodbody <andrew.goodbody@linaro.org>
Reviewed-by: Frieder Schrempf <frieder.schrempf@kontron.de>
The X-Powers AXP323 is very close sibling to the AXP313A, only that it
adds support for dual-phasing the first two DC/DC converters.
We do not really care about this particular feature, so just add the new
compatible string and tie it to the existing AXP313A support code.
Signed-off-by: Andre Przywara <andre.przywara@arm.com>
uclass_find_next_device always returns 0, so instead make it a void and
update calling sites.
Signed-off-by: Andrew Goodbody <andrew.goodbody@linaro.org>
E Shattow <e@freeshell.de> says:
Make consistent use of lowercase hexadecimal prefix '0x' throughout U-Boot.
There are a few remaining uses of uppercase 'X' to denote hexadecimal prefix
or placeholder in documentation and error messages.
External devicetree-rebasing dts/upstream and the generated code of
xilinx/zynq are ignored for the series.
Link: https://lore.kernel.org/r/20250606224558.1117422-1-e@freeshell.de
Use consistent lowercase hex prefix style in drivers/*
Does not change hex prefix case in allcaps uppercase style error messages
Signed-off-by: E Shattow <e@freeshell.de>
Allows use of the regulator functions of the RK8XX PMIC in SPL, which is
necessary to support the functionality of the Rockchip IO-domain driver
on relevant platforms.
Signed-off-by: Justin Klaassen <justin@tidylabs.net>
Reviewed-by: Quentin Schulz <quentin.schulz@cherry.de>
Reviewed-by: Kever Yang <kever.yang@rock-chips.com>
Added a new regulator driver for the MAXIM MAX8907 PMIC, providing
essential regulator functionalities and incorporated the necessary binding
framework within the core PMIC driver.
Tested-by: Ion Agorria <ion@agorria.com>
Signed-off-by: Svyatoslav Ryhel <clamor95@gmail.com>
If there is a SoC specific SCMI protocol driver, using
scmi_proto_driver_get() function can avoid to add SoC specific code to
scmi_agent-uclass.c.
Signed-off-by: Alice Guo <alice.guo@nxp.com>
AXP PMICs have a pin which can either report the USB VBUS state, or
driving a regulator that supplies USB VBUS. Add a regulator driver for
controlling this pin. The selection between input and output is done via
the x-powers,drive-vbus-en pin on the PMIC (parent) node.
Signed-off-by: Samuel Holland <samuel@sholland.org>
Signed-off-by: Andre Przywara <andre.przywara@arm.com>
Reviewed-by: Jernej Skrabec <jernej.skrabec@gmail.com>
The current code attempts to bind scmi_voltage_domain to regulator subnode
of the SCMI protocol node, so scmi_voltage_domain can then bind regulators
directly to subnodes of its node. This kind of behavior should not be in
core code, move it into scmi_voltage_domain driver code. Let the driver
descend into regulator node and bind regulators to its subnodes.
Fixes: 1f213ee4db ("firmware: scmi: voltage regulator")
Signed-off-by: Marek Vasut <marex@denx.de>
[Alice Guo: Fix scmi_regulator_bind]
Signed-off-by: Peng Fan <peng.fan@nxp.com>
Tom Rini <trini@konsulko.com> says:
This series switches to always using $(PHASE_) in Makefiles when
building rather than $(PHASE_) or $(XPL_). It also starts on documenting
this part of the build, but as a follow-up we need to rename
doc/develop/spl.rst and expand on explaining things a bit.
Link: https://lore.kernel.org/r/20250401225851.1125678-1-trini@konsulko.com
It is confusing to have both "$(PHASE_)" and "$(XPL_)" be used in our
Makefiles as part of the macros to determine when to do something in our
Makefiles based on what phase of the build we are in. For consistency,
bring this down to a single macro and use "$(PHASE_)" only.
Signed-off-by: Tom Rini <trini@konsulko.com>
As per TRM[0] Section 8.7.1 "TPS6594-Q1 Registers", LDOx_Vout
bit 6-1, define the NVM voltage settings.
Along side table 8-4 of above TRM, shows voltage to value mapping.
Driver wrongly using bits 5-1 to calculate voltage, and to convert
voltage to value driver was using buck's calculation.
So fix those calculation.
[0]: https://www.ti.com/lit/ds/symlink/tps6594-q1.pdf
Fixes: 5d7dbd22cf ("power: regulator: tps65941: use function callbacks for conversion ops")
Signed-off-by: Udit Kumar <u-kumar1@ti.com>
Reviewed-by: Neha Malcom Francis <n-francis@ti.com>
Replace magic numbers in buckval2votl() & buckvolt2val() with macros to
help with clarity and correlate what the numbers correspond to in the
TPS65219 datasheet.
Signed-off-by: Shree Ramamoorthy <s-ramamoorthy@ti.com>
Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com>
Replace printf() with pr_err() because pr_err() has a uniform print format
and takes into consideration the log levels supported.
Signed-off-by: Shree Ramamoorthy <s-ramamoorthy@ti.com>
Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com>
Simon Glass <sjg@chromium.org> says:
When the SPL build-phase was first created it was designed to solve a
particular problem (the need to init SDRAM so that U-Boot proper could
be loaded). It has since expanded to become an important part of U-Boot,
with three phases now present: TPL, VPL and SPL
Due to this history, the term 'SPL' is used to mean both a particular
phase (the one before U-Boot proper) and all the non-proper phases.
This has become confusing.
For a similar reason CONFIG_SPL_BUILD is set to 'y' for all 'SPL'
phases, not just SPL. So code which can only be compiled for actual SPL,
for example, must use something like this:
#if defined(CONFIG_SPL_BUILD) && !defined(CONFIG_TPL_BUILD)
In Makefiles we have similar issues. SPL_ has been used as a variable
which expands to either SPL_ or nothing, to chose between options like
CONFIG_BLK and CONFIG_SPL_BLK. When TPL appeared, a new SPL_TPL variable
was created which expanded to 'SPL_', 'TPL_' or nothing. Later it was
updated to support 'VPL_' as well.
This series starts a change in terminology and usage to resolve the
above issues:
- The word 'xPL' is used instead of 'SPL' to mean a non-proper build
- A new CONFIG_XPL_BUILD define indicates that the current build is an
'xPL' build
- The existing CONFIG_SPL_BUILD is changed to mean SPL; it is not now
defined for TPL and VPL phases
- The existing SPL_ Makefile variable is renamed to SPL_
- The existing SPL_TPL Makefile variable is renamed to PHASE_
It should be noted that xpl_phase() can generally be used instead of
the above CONFIGs without a code-space or run-time penalty.
This series does not attempt to convert all of U-Boot to use this new
terminology but it makes a start. In particular, renaming spl.h and
common/spl seems like a bridge too far at this point.
The series is fully bisectable. It has also been checked to ensure there
are no code-size changes on any commit.
Use PHASE_ as the symbol to select a particular XPL build. This means
that SPL_TPL_ is no-longer set.
Update the comment in bootstage to refer to this symbol, instead of
SPL_
Signed-off-by: Simon Glass <sjg@chromium.org>
The pmic could be trimed with updated BUCK1 range, so update the range
for trimed pmic. The default value of Toff_Deb is used to distinguish
the non-trimed and trimed pmic.
Signed-off-by: Joy Zou <joy.zou@nxp.com>
Reviewed-by: Ye Li <ye.li@nxp.com>
Signed-off-by: Peng Fan <peng.fan@nxp.com>
Both regulators_enable_boot_on/off() are unused and superseded by
regulator uclass regulator_post_probe(). Remove both functions.
Signed-off-by: Marek Vasut <marex@denx.de>
Turn regulators_enable_boot_on() and regulators_enable_boot_off() into
empty functions. Implement matching functionality in regulator_post_probe()
instead. The regulator_post_probe() is called for all regulators after they
probe, and regulators that have regulator-always-on or regulator-boot-on DT
properties now always probe due to DM_FLAG_PROBE_AFTER_BIND being set on
such regulators in regulator_post_bind().
Finally, fold regulator_unset() functionality into regulator_autoset().
Signed-off-by: Marek Vasut <marex@denx.de>
In case a regulator DT node contains regulator-always-on or regulator-boot-on
property, make sure the regulator gets correctly configured by U-Boot on start
up. Unconditionally probe such regulator drivers. This is a preparatory patch
for introduction of .regulator_post_probe() which would trigger the regulator
configuration.
Parsing of regulator-always-on and regulator-boot-on DT property has been
moved to regulator_post_bind() as the information is required early, the
rest of the DT parsing has been kept in regulator_pre_probe() to avoid
slowing down the boot process.
Signed-off-by: Marek Vasut <marex@denx.de>
The buck variable is zero based, i.e. buck=0 match BUCK1 in datasheet.
Remove any buck + 1 calculation to be more consistent in usage of the
buck variable across the different RK8xx variants in the driver.
Signed-off-by: Jonas Karlman <jonas@kwiboo.se>
Reviewed-by: Kever Yang <kever.yang@rock-chips.com>
Wrong POWER_EN reg is used to get and set enabled state for the RK806
buck 4 and 8 regulators, also wrong POWER_SLP_EN0 bit is used for
suspend state for the RK806 buck 1-8 regulators.
Fix this by not adding one to the zero based buck variable.
Fixes: f172575d92 ("power: rk8xx: add support for RK806")
Signed-off-by: Jonas Karlman <jonas@kwiboo.se>
Reviewed-by: Kever Yang <kever.yang@rock-chips.com>
Reviewed-by: Quentin Schulz <quentin.schulz@cherry.de>
dev_get_driver_ops() may return NULL when the udevice is invalid.
Move the ops check to top of functions to consistently return -ENOSYS
when ops is unimplemented and prevent trying to access uclass plat data,
also add missing NULL checks to suspend ops.
Signed-off-by: Jonas Karlman <jonas@kwiboo.se>
On some boards a PMIC regulator is flagged with regulator-on-in-suspend
and does not define any suspend or max microvolt, e.g. on Radxa ROCK 3A:
vcc_ddr: DCDC_REG3 {
regulator-name = "vcc_ddr";
regulator-always-on;
regulator-boot-on;
regulator-initial-mode = <0x2>;
regulator-state-mem {
regulator-on-in-suspend;
};
};
This result in suspend_uV having the value -ENODATA after probe.
This negative voltage, -ENODATA, gets missinterpreted and result in an
unexpected voltage being set by autoset.
E.g. on Radxa ROCK 3A the vcc_ddr regulator by default have a normal and
suspend voltage value of 0.5v. However, due to this missinterpretation
the suspend voltage end up beind set to 0.5625v instead.
Fix this by skip calling regulator_set_suspend_value() in autoset and
also protect calling set value ops when input value is -ENODATA.
Signed-off-by: Jonas Karlman <jonas@kwiboo.se>
Various improvements to Snapdragon support:
* Bumped up the pagetable size to handle newer SoCs with much more RAM
* Made memory map parsing more robust, fixing chainloading on
SM8550/SM8650
* Populate fdt_addr_r with U-Boot's FDT by default, and set $loadaddr to
prevent
crashes with some commands which expect it
* Added initial support for SC7280/QCM6490 and the new RB3 Gen 2 board
* Add debug config fragments to enable debug UART on some SoCs.
* Enable RPMh regulators on SM8550/SM8650
* Map the cmd-db memory explicitly since it may not be in the memory map
CI: https://source.denx.de/u-boot/custodians/u-boot-snapdragon/-/pipelines/22255