The regulator bindings state that regulator prefixes are allowd to be in upper or lower case. However pmic_bind_children from pmic_uclass uses strncmp to compare DT node name against prefix. This comparison is case sensitive hence the regulator driver prefix case matters. Signed-off-by: Felix Brack <fb@ltec.ch>